THE EXPERIENCE TO SAFEGUARD YOUR INFRASTRUCTURE PROJECT
Corrosion Control Testing Services
Blue Ridge Corrosion, LLC (BRC) is a Virginia-based SWaM
certified business providing testing and troubleshooting services
for infrastructure projects with corrosion mitigation specifications. BRC will safely and efficiently work with your team to ensure
the project milestones are met from kickoff to closeout.
KEY SERVICES
Visual Inspection
This service is a review of the infrastructure asset requiring corrosion testing.
We provide this service to:
1. Ensure measured field data is accurate for analysis and reporting.
2. Identify potential issues with the asset that may require future troubleshooting.
Our process ensures downtime due to rework and additional retesting is kept to a minimum.

Inside a Formed Retaining Wall to Verify
Proper Welding for Electrical Continuity Testing

Inside a METRO Tunnel to Document
Conditions Prior to Track-to-Earth Testing
Electrical Continuity
Electrical continuity is required for stray current mitigation and cathodic protection.
BRC specializes in rebar testing which is a necessary requirement for rail transit projects.
Rebar testing: An electrical circuit is created by welding the steel reinforcment (rebar)
within a reinforced concrete structure with bond jumpers at joints as necessary. Testing is
completed pre-embedment with concrete (prepour) and post-embedment with concrete (postpour).
Rebar testing confirms the structure will be within project specifications during its design life.

Electrical Continuity Test Equipment

Electrical Continuity Test Equipment Static Measurements
(Off Reads) Prior to Application of Test Current

Electrical Continuity Test Equipment Energized Measurements
(On Reads) During Application of Test Current

Electrical Continuity Prepour Testing of a
Bonded (Welded) Retaining Wall Footing

Electrical Continuity Prepour Testing of a
Bonded (Welded) Retaining Wall
Data Analysis
We employ classic mathematical circuit analysis alongside computer circuit modeling
software techniques to verify and report test results from field measured data.

Simulation Program with Integrated Circuit Emphasis (SPICE) Model
of a Bonded Reinforced Concrete Structure

Bonded Track Slab
Track-to-Earth Testing
We verify track sections are electrically isolated from ground and adjacent structures.
Additionally, we troubleshoot track components.
Troubleshooting
Testing performed to determine the root cause of structures with
deficient measured test values and/or nonconforming work.

Testing the Influence of Stray Current on an Underground Waterline Adjacent to a METRO
Get in touch
Telephone: 215-429-9892
E-mail: srivera@blueridgecorrosion.com
Address: Berryville, 22611, Virginia, United States